Danfoss HVAC Drives and Pressure Transmitters in Pakistan

In a building’s HVAC plant, a variable frequency drive adjusts pump or fan speed as demand changes. A pressure transmitter gives the control system a measurement it can display, trend or use as feedback. For procurement teams, the two items require different information on the enquiry. The drive is specified from the motor and its duty, while the transmitter is specified from the pressure measurement and the receiving input.

HAT INDUSTRIES independently sources Danfoss HVAC drives and pressure transmitters on demand for customers in Pakistan. We hold no supplier, distributor or partner authorization from Danfoss or any other brand.

Danfoss VLT HVAC Drive FC 102 for pumps and fans

The Danfoss VLT HVAC Drive FC 102 is a variable frequency drive (VFD) for HVAC motor control. In a chilled-water plant, an FC 102 can adjust the speed of a circulation pump. In an air handling unit, it can vary supply fan speed according to the system’s control strategy.

If the project already specifies the drive, send the full Danfoss type code. For a new selection, include the motor nameplate voltage, full-load current and power, incoming supply voltage and phase, pump or fan duty, enclosure requirements and any wired building management system (BMS) interface. These details help identify the configuration to quote.

Danfoss MBS 1900 pressure transmitters for water systems

The Danfoss MBS 1900 pressure transmitter is designed for air and water applications, including booster pumps. In a building water system, a gauge-pressure version can measure pump discharge pressure at a single point. A compatible 4–20 mA version can send that reading to a controller or BMS analogue input.

For an MBS 1900 enquiry, send the full Danfoss product code if known. Otherwise, specify the pressure range, whether the measurement is gauge or absolute, the medium and its temperature, the process connection thread, the output signal and the electrical connector. Confirm that the transmitter range suits both normal operation and the pressures expected at startup and shutdown.

How pressure feedback is used with an HVAC drive

On a pressure-controlled pump, the system can use a compatible pressure signal to compare the measured value with a setpoint and adjust motor speed. First identify what the design is trying to maintain. Pump discharge pressure is measured at one point. Differential pressure is the difference between two points, such as the supply and return of a chilled-water circuit. The MBS 1900 example above is for single-point pressure measurement. For a differential-pressure loop, specify a measurement arrangement that matches the design.

Frequently asked questions

How do I get a Danfoss FC 102 or MBS 1900 price in Pakistan?

Send HAT INDUSTRIES the full drive type code or transmitter product code, quantity, delivery city and required date. If the item is still being specified, attach the motor nameplate or pressure instrument schedule. Pricing and estimated lead time depend on the exact configuration and availability.

Can I request a quote for both the HVAC drive and pressure transmitter?

Yes. Send one bill of materials with separate lines for the drive and transmitter. Include the motor ratings for the drive and the pressure range, connection and output signal for the transmitter.

See the drive and pressure instrumentation sections of our Danfoss products guide for Pakistan.

Planning a pump or air handling project? Contact HAT INDUSTRIES for a Danfoss sourcing quote with your equipment schedule or bill of materials.