Danfoss VLT HVAC Drive FC 102 & MCD 202 Soft Starters

Danfoss part numbers are hard to read at first glance. A VLT drive can have a short 7-character ordering number and a 40-character type code. Two drives with the same kW rating can differ in enclosure, RFI filter, or fieldbus option. Ordering from only the kW rating is the most common reason a drive turns up wrong.

HAT INDUSTRIES helps businesses across Pakistan identify and source Danfoss drives and soft starters. We are not an authorized Danfoss distributor or stockist. Every order is sourced on request through established, authorized channels, and we confirm the full type code with you before ordering.

Reading an FC 102 Type Code

Take this example: FC-102P30KT4P21H2XGCXXXSXXXXAXBXCXXXXDX

SegmentMeaning
FC-102VLT HVAC Drive
P30K30 kW / 40 HP
T4Three phase, 380–480 VAC
P21IP21 / Type 1 enclosure (E20 = IP20, E55 = IP55)
H2RFI filter (H1 = Class A1/B)
Remaining charactersBrake option, display, coating, and fieldbus options

Pakistan’s industrial supply is 380–415 V, three phase, so the “T4” voltage class is the one most panels need.

Verified FC 102 Examples (380–480 VAC, Three Phase)

Ordering NumberPowerEnclosure
131B42305.5 kW / 7.5 HPIP55 / Type 12
131H949515 kW / 20 HPIP20 / Chassis, RFI Class A1/B
131L022722 kW / 30 HPIP20 / Chassis
131B427430 kW / 40 HPIP21 / Type 1
131B700937 kW / 50 HPIP55 / Type 12
131F662875 kW / 100 HPIP20 / Chassis

Choose the enclosure by where the drive will sit. IP20 is for inside a clean panel, IP21 suits a protected indoor wall mount, and IP55 suits dusty or splash-exposed areas without a panel.

MCD 202 Compact Soft Starters

The MCD 202 is a compact soft starter for simple pump, fan, compressor, mixer and conveyor starting. It reduces inrush current and mechanical shock but does not provide speed control.

The model name tells you the rating:

SegmentMeaning
MCD 202-055Current/power class (055 = 55 kW, 100 A)
T4 / T6Voltage range: T4 = 200–440 VAC, T6 = 200–575 VAC
CV1 / CV3Control voltage: CV1 = 24 VAC/VDC, CV3 = 110–240 VAC
Ordering NumberModelRated Current
175G5209MCD 202-007-T4-CV318 A
175G5210MCD 202-015-T4-CV334 A
175G5212MCD 202-022-T4-CV348 A
175G5216MCD 202-055-T4-CV3100 A
175G5227MCD 202-055-T4-CV1100 A
175G5218MCD 202-090-T4-CV3170 A

Models 175G5216 and 175G5227 are both 100 A, but they differ in control voltage (110–240 VAC versus 24 VAC/VDC). Checking this before ordering avoids a common wiring mismatch.

Soft Starter or VFD?

NeedBetter Fit
Smoother start, no speed controlMCD 202 soft starter
Variable speed, energy saving on pumps and fansFC 102 drive
Lower cost on a fixed-speed motorMCD 202 soft starter

Frequently Asked Questions

What information do you need to quote an FC 102?
The full type code from the drive label is best. If the label is unreadable, send the motor kW, voltage, enclosure preference, and any fieldbus requirement.

Why do two FC 102 drives with the same kW have different ordering numbers?
The enclosure, RFI filter, and options all change the ordering number. For example, 131B7009 (IP55) and 131H4597 (IP20) are both 37 kW drives.

Can an MCD 202 run on Pakistan’s 400 V supply?
Yes, the T4 version covers 200–440 VAC. Confirm the control voltage (CV1 or CV3) against your panel’s control supply.

Do you keep these in stock?
No. We source on demand and confirm availability, pricing, and lead time before you commit.

Request a Quote

Send us the part number, the full type code, or your motor’s kW, voltage, and application, and HAT INDUSTRIES will confirm the right match, availability, and pricing.