Lenze 8200 vector & 8400 StateLine C Inverters

Many packaging, textile and material handling machines in Pakistan still run Lenze 8200 vector or 8400 StateLine inverters. When one fails, the machine’s nameplate often gives only a partial type code. Lenze type codes carry the power, voltage and hardware version in a few characters, so a one-letter mistake can mean the wrong drive.

HAT INDUSTRIES helps businesses across Pakistan identify and source Lenze inverters. We are not an authorized Lenze distributor or stockist. Every order is sourced on request through established, authorized channels, and we confirm the full type code with you before ordering.

Reading a Lenze 8200 vector Type Code

Take this example: E82EV152K4C200

SegmentMeaning
E82EV8200 vector inverter
152Power: 15 × 10² W = 1.5 kW
K2 / K4Voltage class: K2 = 230 V, K4 = 400/500 V
B / CHardware version
200 (suffix)Version without integrated EMC filter

Lenze’s own manual gives the power code as digits that read as ×10^n watts, so 152 is 1.5 kW and 371 is 0.37 kW.

Verified 8200 vector Examples

TypePowerSupplyNotes
E82EV251K2B0.25 kW1/N/PE, 180–264 V ACIntegrated EMC filter
E82EV371K2B0.37 kW1/N/PE, 180–264 V ACIntegrated EMC filter
E82EV371-2C0.37 kW230/240 V, single phaseC hardware version
E82EV152K4B1.5 kW3-phase, 400/500 VIP20, 3.9 A (400 V) / 3.1 A (500 V)
E82EV152K4C1.5 kW3-phase, 400/480 VIntegrated EMC filter
E82EV152K4C2001.5 kW3-phase, 400/480 VWithout EMC filter
E82EV222K4C2.2 kW3-phase, 400 VC hardware version

The B and C versions are different hardware generations, so check the exact letter on your nameplate rather than assuming they are interchangeable. Many 8200 vector units also carry a function module such as the E82ZAFSC010, which provides digital and analog I/O control. Include it in your quote request if your unit has one.

Verified 8400 StateLine C Examples

The 8400 StateLine is a panel-mounted inverter for general-purpose and intralogistics-style duty. Its specifications include IP20 protection, output frequency of 0–599 Hz, integrated brake management, an optional EMC filter, and on-board I/O (4 digital inputs, 1 analog input, 1 analog output, 1 digital output).

TypePowerSupplyRated Output Current
E84AVSCE7512SX00.75 kW1-phase, 230 V4.0 A
E84AVSCE7514SB00.75 kW3-phase, 400/500 V2.4 A / 1.9 A
E84AVSCE7514SB70.75 kW3-phase, 400 V2.4 A / 1.9 A
E84AVSCE7514SX00.75 kW3-phase, 400 V2.4 A

The characters at the end of the type code (SB0, SB7, SX0) identify the variant. Copy them exactly from the nameplate, because drives with the same power and voltage can still differ in options.

Which One Fits?

SituationLook At
Simple speed control on a small machine8200 vector
Machine needs brake management and on-board I/O8400 StateLine C
Replacing a failed drive in an existing machineThe exact type code on the nameplate

For new machine builds, many users choose Lenze’s current i550 platform. Share your nameplate details if you’d like help comparing a like-for-like replacement with an upgrade.

Frequently Asked Questions

What if my nameplate is unreadable?
Send us the motor kW, supply voltage, the drive’s frame size or photo, and any function module fitted. We’ll work out the closest match and confirm it with you before ordering.

Does the “200” at the end of an 8200 vector type code matter?
Yes. It indicates the version without the integrated EMC filter, so it is not the same part as the filtered version.

Can I swap a B-version 8200 vector for a C-version?
Not automatically. Confirm compatibility first, including the function module and wiring.

Do you keep these in stock?
No. We source on demand and confirm availability, pricing, and lead time before you commit.

Request a Quote

Send us the full type code, a photo of the nameplate, or your motor’s kW, voltage and application, and HAT INDUSTRIES will confirm the right match, availability, and pricing.