Mitsubishi Electric FR-E800 and FR-F800 Inverters in Pakistan

A Mitsubishi inverter model number tells you the voltage class, the current rating and the motor size, but only if you know how to read it. Ordering by kW alone is a common mistake, because the same motor power can map to different models depending on whether the load is general-purpose or a variable-torque fan or pump.

HAT INDUSTRIES helps businesses across Pakistan identify and source Mitsubishi Electric inverters. We are not an authorized Mitsubishi Electric distributor or stockist. Every order is sourced on request through established, authorized channels, and we confirm the full model number with you before ordering.

Decoding the Model Number

Take this example: FR-E840-0016-4-60

SegmentMeaning
FR-EFREQROL E series
840Voltage class: 820 = 200 V three-phase, 820S = 200 V single-phase, 840 = 400 V class
0016Rated output current code (0016 = 1.6 A)
4-60Version and regional suffix, copied exactly from the nameplate

Pakistan’s industrial supply is 380–415 V three phase, so the 840 (400 V class) models are the usual choice for three-phase motors. Use the 820S for small single-phase installations.

FR-E800 Compact General-Purpose Inverters (400 V Class)

ModelMotor (ND)Rated Current (ND)
FR-E840-00160.4 kW1.6 A
FR-E840-00260.75 kW2.6 A
FR-E840-00401.5 kW4 A
FR-E840-00602.2 kW6 A
FR-E840-00953.7 kW9.5 A
FR-E840-01707.5 kW17 A
FR-E840-030015 kW30 A
FR-E840-044022 kW44 A

A fully ordered example is FR-E840-0016-4-60, a 0.4 kW inverter (0.75 kW in light duty) for 3 × 380–480 V, with 1.6 A normal-duty output and RS-485 communication in an IP20 body. The E800 also comes in single-phase 200 V versions (FR-E820S-0008 to 0110, 0.1–2.2 kW). Versions ending in E or SCE add communication options, so copy the suffix exactly.

FR-F800 Fan and Pump Inverters (400 V Class)

The FR-F800 is built for variable-torque loads such as centrifugal fans and pumps, with an advanced PID controller and an integrated EMC filter.

ModelMotor Power
FR-F840-00023-2-600.75 kW
FR-F840-00052-2-602.2 kW
FR-F840-00126-2-605.5 kW
FR-F840-00170-2-607.5 kW
FR-F840-00310-2-6015 kW
FR-F840-00470-2-6022 kW
FR-F840-01160-2-6055 kW
FR-F840-02160-2-6090 kW

For example, the FR-F840-00170-2-60 is a 7.5 kW, three-phase, 380–500 V inverter with 17 A output (16 A in light duty) in an IP20 body. One retailer notes that newer production, such as the FR-F840-00170-E2-60, replaces the -2-60 and has an Ethernet card fitted as standard, so confirm which version you need.

E800 or F800?

LoadBetter Fit
Conveyors, mixers, small machines, general-purpose speed controlFR-E800
Centrifugal pumps and fans (variable torque)FR-F800
Small single-phase installationFR-E820S

Frequently Asked Questions

What do ND, LD and SLD mean on the data sheet?
They are overload duty ratings (normal, light and super light duty). The same inverter has a higher current rating under lighter duty, so size it for your actual load.

Can I order by kW only?
It’s risky. Send the motor’s rated current and voltage as well, and the full model number if you have it.

Does the suffix matter?
Yes. Versions with different suffixes can differ in communication options or safety features, so copy the suffix exactly.

Do you keep these in stock?
No. We source on demand and confirm availability, pricing, and lead time before you commit.

Request a Quote

Send us the model number from your existing inverter, or your motor’s kW, current, voltage and load type, and HAT INDUSTRIES will confirm the right match, availability, and pricing.